ÍST EN ISO 10993-1:2025

Staða:

Gildistaka - 6.2.2026

Íslenskt heiti:

Líffræðilegt mat á lækningatækjum – Hluti 1: Kröfur og almennar meginreglur fyrir mat á líffræðilegu öryggi innan áhættustjórnunarkerfis

Enskt heiti:

Biological evaluation of medical devices - Part 1: Requirements and general principles for the evaluation of biological safety within a risk management process (ISO 10993-1:2025)

Tengdur staðall:

ISO 10993-1:2025

Tækninefnd:

CEN/TC 206

ICS flokkur:

11.100

Auglýst:

5.2.2026

Umfang (scope):

This document specifies the requirements and general principles governing the biological evaluation of medical devices within a risk management process according to ISO 14971. This document applies to the biological evaluation of medical devices that have direct contact or indirect contact with either: —     a patient's body during intended use or reasonably foreseeable misuse; or —     the body of other users who are not patients, if the medical device is intended for personal protection (e.g. medical gloves, surgical masks). Biological evaluation assesses the biological safety of the medical device by considering the biological risks associated with: —     constituents of a medical device; and —     tissue-device interactions (including physical effects). The biological evaluation specified in this document can address the biological safety of the medical device, considering the life cycle from design and development through initial use of the finished medical device to final decommissioning or withdrawal from use. The biological evaluation considers both the biological safety of the finished device in first use, and the significance of any changes to the medical device which can occur throughout the life cycle. However, the evaluation of risks related to environmental impacts of decommissioning of medical devices are not within the scope of this document. This document does not mandate re-testing of medical devices that are already on the market and have established and acceptable safety profiles (see 6.6.2). This document can be useful to support clinical or usability evaluations of medical devices. For example, a biological evaluation is a pre-requisite for conducting a clinical trial. This means that principles outlined in this document can be applied to the evaluation of prototype or development stage devices, as well as to finished medical devices. Other parts of the ISO 10993 series cover specific aspects of biological evaluation, such as chemical characterization, biological testing, sample preparation, animal welfare and toxicological risk assessment. For some types of medical devices, specific requirements from other standards (outside the ISO 10993 series) can be considered with a justification for the approach taken if there are differences between the requirements of the ISO 10993 series and those provided in other standards. For example, the ISO 18562 series provides specific requirements for biological evaluation of breathing gas pathway medical devices and ISO 7405 provides specific requirements for biological evaluation of dental devices. The evaluation of risks related to infectious agents [e.g. bacteria, moulds, yeasts, viruses, transmissible spongiform encephalopathy (TSE) agents] is not within the scope of this document. NOTE 1        The evaluation of bacterial endotoxins is addressed by ISO 11737-3. NOTE 2        The evaluation of risks related to viruses, TSE agents and other pathogens originating from materials of animal origin is addressed by the ISO 22442 series.
Verð 15.498 kr.
Skráðu þig inn til þess að skoða sýnishorn
Skráðu þig inn til þess að vakta þennan staðal
Skráðu þig inn til þess að kaupa þennan staðal
* Mynd sem fylgir ÍST EN ISO  10993-1:2020

ÍST EN ISO 10993-1:2020

This document specifies: — the general principles governing the biological evaluation of medical devices within a risk management process; — the general categorization of medical devices based on the nature and duration of their contact with the body; — the evaluation of existing relevant data from all sources; — the identification of gaps in the available data set on the basis of a risk analysis; — the identification of additional data sets necessary to analyse the biological safety of the medical device; — the assessment of the biological safety of the medical device. This document applies to evaluation of materials and medical devices that are expected to have direct or indirect contact with: — the patient's body during intended use; — the user's body, if the medical device is intended for protection (e.g., surgical gloves, masks and others). This document is applicable to biological evaluation of all types of medical devices including active, non-active, implantable and
Verð: 14.248 kr.